1. PRODUCT DESCRIPTION



Clevises are mechanical linking units suitable for the transmission of static forces. The pins or the lockable pins, used in conjunction with the clevises, have the function of connecting the clevis with the mechanical part for the transmission of the force. They are standard products, which are produced according to the norms and the indicated dimensional tables. All our products can be supplied galvanized or unplated.


2. TECHNICAL DATA

· Clevis type G DIN 71752 norm
· Clevis type G . . FG DIN 71752 norm with thread ISO 8140
· Clevis type G . . CN t CNOMO 06 07 14 norm
· Mating piece for clevis type G . .FG according to dimensional tables
· Pin type PDIN DIN 1434 norm
· Pin type PKS according to dimensional tables
· Pin type PI according to dimensional tables
· Pin type PC according to dimensional tables
Materiale:
Automatic Steel 11SMnPb30 (1.0718) COLD-DRAWN (+C) EN 10277-3 NORM
   
· Clevis type G . . STAINLESS STEEL DIN 71752 norm
· Clevis type G . . FG STAINLESS STEEL DIN 71752 norm with thread ISO 8140
· Mating piece for clevis type G . .FG STAINLESS STEEL according to dimensional tables
· Pin type PI . .STAINLESS STEEL according to dimensional tables
Materiale:
Stainless Steel AISI 303 (1,4305) COLD-DRAWN (+C) EN 10088-3 NORM
   
· Clevis type GA . . DIN 71752 norm
· Clevis type GA . . FG DIN 71752 norm with thread ISO 8140
· Pin type PKSAL . . according to dimensional tables
Materiale:
Aluminium 2011 (11S) anodized COLD-DRAWN EN 754 NORM
   
· Lockable pin type PM according to dimensional tables
· Lockable pins type PMC according to dimensional tables
Materiale:
Pin - automatic steel 11SMnPb30 (1,0718)
Spring - carbon steel C67 (1,0603)

Static load

By static load we mean the maximum radial load which, when applied to the forks in a static way, does not create permanent deformations or prejudice its functioning. The values of the maximum permissible load were obtained by calculation and then verified on significant samples taken from our production series. In the tables of dimensions the permissible static loads (Co) which are indicated have been calculated on the basis of a minimum safety factor of 2.5 times with respect to the breaking static load. Where pulsating or alternating loads are used, it is necessary to reduce the permissible static load introducing the safety coefficient Kf:

It is important always to verify the following condition:

3. TOLERANCES

The constructional tolerances refer to current regulations or to those specified in the tables of dimensions.
HEAD OFFICE - BOLOGNA
  • Address: Via G. Brodolini 6-8-10
  • 40069 Zola Predosa, Bologna
  • Phone: +39 – 051 75 87 67
  • Fax: +39 – 051 75 47 80
  • Fax sales dept.: +39 – 051 615 51 26
  • Email: tescubal@chiavette.it